@SmitHVAC.2 years agoFun fact if you don' t have the manual it says the high and low ratings right on the sticker on the solenoid. 14
@
@MartinLDeLoach903last yearAs a hvac tech i approve of the video message. Not only is the gas pressure on sililiniod but on gv itself. You just forgot to say. Do not turn the little. ...Expand4
@
@Strictly4Defense2 years agoYou' re outside working on package gas furnace possibly a commercial rtu. But when working on residential furnace we have to set the gas pressure according. ...Expand7
@
@daprincebun2 years agoBeen working for a company for about 3 months and in school and havent been taught this thanks now next furnace gs i can actually do this. 7
@
@davidnunez788910 months agoThank you for the video good explanation. 1
@
@MartinLDeLoach903last yearAnother fun fact, put the hose on inlet port, and you can find out if the gv is getting enough gas pressure to the gv from the gas manifold to run the gas furnace. 2
@
@FATBOYROY43702 years agoGood teaching we did not have that kind of training back in 89. 2
@
@keithmcguire664811 months agoMore information setting gas pressure love it. 1
@
@Georges3DPrinterslast yearAnd did you clock the gas meter? All set to the 3. 5 psi is not clocking gas meter for actual output compensation. But i only just started doing the clocking. ...Expand2
@
@phillipthethird42last yearYep, that' s right. but next time, do it with an old school water column. 2
@
@jesushurtado1354last yearRecently encountered a carrier ultra low knox furnace and the ports to check my pressure were a different size than what usually works with my field piece adapters anyone encounter this? 2
@
@MartinLDeLoach903last yearFor those that don' t know, on the adjustment screws, it is a quarter turn! 1
@
@jamesortolano39832 years agoIn the early 20' s when we were installing lennox. theall had low settings on second stage. i dont think any adjusted to 3. 5. Which meant they were not heating efficiently. since then i' ve checked every unit, from every manufacturer, nd on more than half of what i' ve put in they all are to low. great video for all the new guys, nd a good tool to have in the service bag. ...Expand1
@
@edwardgaddis8333last yearGood reminder thanks. My new manometer came in today as well. 1
@
@MartinLDeLoach903last yearAlso me. Who why the hell are rolling 3. 71 wc. Way too high. Are you trying to turn the furnace in a rocket mode. 1
@
@abazismlast yearIs the testing port the same for both stages? 1
@
@acrservicesmathewr75652 years agoDoes it really matter doing the high side first? I was told it doesnt make much diff on rtus. 1
@
@sumdumguy4659last yearThe real question is why would you own a two stage furnace. Lol 1 btu is 1 btu. 1
@
@MartinLDeLoach903last yearAs a hvac tech i approve of the video message. Not only is the gas pressure on sililiniod but on gv itself. You just forgot to say. Do not turn the little. ...Expand4
@
@Strictly4Defense2 years agoYou' re outside working on package gas furnace possibly a commercial rtu. But when working on residential furnace we have to set the gas pressure according. ...Expand7
@
@Georges3DPrinterslast yearAnd did you clock the gas meter? All set to the 3. 5 psi is not clocking gas meter for actual output compensation. But i only just started doing the clocking. ...Expand2
@
@jamesortolano39832 years agoIn the early 20' s when we were installing lennox. theall had low settings on second stage. i dont think any adjusted to 3. 5. Which meant they were not heating efficiently. since then i' ve checked every unit, from every manufacturer, nd on more than half of what i' ve put in they all are to low. great video for all the new guys, nd a good tool to have in the service bag. ...Expand1
Related videos for How to set gas pressure for 2 Stage Heat @FieldpieceProducts:
but next time, do it with an old school water column. 2
theall had low settings on second stage.
i dont think any adjusted to 3. 5. Which meant they were not heating efficiently.
since then i' ve checked every unit, from every manufacturer, nd on more than half of what i' ve put in they all are to low.
great video for all the new guys, nd a good tool to have in the service bag. ...Expand 1
theall had low settings on second stage.
i dont think any adjusted to 3. 5. Which meant they were not heating efficiently.
since then i' ve checked every unit, from every manufacturer, nd on more than half of what i' ve put in they all are to low.
great video for all the new guys, nd a good tool to have in the service bag. ...Expand 1